定义Definition
比旋光度是把观测旋光角归一化到 1 dm 光程和 1 g/mL 浓度的旋光度,[α]ᵀ_λ = α/(l·c),是手性化合物的特征物理常数。
Specific rotation is the observed rotation normalised to a 1 dm path and 1 g/mL concentration, [α]ᵀ_λ = α/(l·c) — a characteristic physical constant of a chiral compound.
单位与规范Units and conventions
l 以 dm、c 以 g/mL(纯液体用密度)代入;严格单位为 deg·mL·g⁻¹·dm⁻¹,习惯只写度数。报告时注明温度、波长(D 线 589 nm)、溶剂和浓度,如 [α]²⁰_D = +66.5(c 1.0,H₂O)。
Use l in dm and c in g/mL (density for neat liquids); the unit deg mL g⁻¹ dm⁻¹ is usually omitted. Report temperature, wavelength (D line, 589 nm), solvent and concentration, e.g. [α]²⁰_D = +66.5 (c 1.0, H₂O).
用途Uses
鉴定手性化合物、测定光学纯度(ee ≈ [α]观测/[α]纯)、监测蔗糖转化(右旋蔗糖水解为左旋的“转化糖”)和糖的变旋现象。
Identifying chiral compounds, estimating optical purity (ee ≈ [α]obs/[α]pure), following sucrose inversion (dextrorotatory sucrose → laevorotatory invert sugar) and sugar mutarotation.
注意Caveats
比旋光度的正负与 R/S 构型无对应关系;不同溶剂、pH 下符号甚至可反转(如乳酸)。少量高旋光杂质会严重影响结果,现代 ee 测定多用手性色谱。
The sign does not map onto R/S, and can even reverse with solvent or pH (lactic acid). Small amounts of highly rotating impurities distort results; modern ee measurements use chiral chromatography.
年表Timeline
- 1815
毕奥建立旋光度与浓度、光程的正比关系
Biot establishes proportionality to concentration and path length
- 1840s
旋光法用于糖业检测(糖量计)
Polarimetry adopted in the sugar industry (saccharimeters)
相关公式Formulas
例题Worked example
蔗糖 [α]D²⁰ = +66.5°;c = 0.10 g/mL、l = 2 dm 时 α = +13.3°。
Sucrose [α]D²⁰ = +66.5°; at c = 0.10 g/mL, l = 2 dm, α = +13.3°.